4E
DTC is Not Outputted Even with Diag. Switch Terminal Connected to Ground
Wiring Diagram
Circuit Description
Troubleshooting
Step Action YES NO
1
1) Turn ignition switch to ON position.
Is it shorted diag. switch terminal and ground terminal by service wire properly?
Go to Step 2.
Connect service wire securely.
2
1) Disconnect service wire.
2) Check the ABS lamp operation. Refer to “ABS” Warning Lamp Check .
Does ABS lamp operate properly?
Go to step 3.
3
1) Turn ignition switch to OFF position.
2) Disconnect ABS hydraulic unit / control module connector.
3) Check for proper connection to ABS hydraulic unit / control module at terminal “E142-18”.
4) If OK, measure resistance between diag. switch terminal and “E142-18” terminal.
Is it infinite (∞)?
“PNK” wire circuit open.
Go to Step 4.
4
1) Measure resistance between ground terminal of monitor connector and vehicle body ground.
Is continuity indicated?
Substitute a known-good ABS hydraulic unit / control module and recheck.
“BLK” circuit open or poor connector.