9C
Fuel Level Meter Inspection
1) Disconnect negative cable at battery.
2) Disconnect floor harness connector (3) (White connector).
3) Using service wire, short terminal (1) and (2) of floor harness connector (3).
4) Connect negative cable to battery and then turn ignition switch to ON position. Make sure that the meter pointer (4) moves from the position “E”.
If fuel level meter does not operate, check wire harness between floor harness connector and combination meter connector.
If wire is OK, replace combination meter.