7B
Refrigerant Pressure Sensor Removal and Installation
Removal
1) Recover refrigerant referring to “Recovery” in Operation Procedure for Refrigerant Charging .
2) Disconnect negative (–) cable at battery.
3) Disconnect refrigerant pressure sensor connector.
4) Remove refrigerant pressure sensor from pipe.
Installation
Reverse removal procedure noting the following points.
• Apply compressor oil to refrigerant pressure sensor O-ring.
• Perform evacuation, and then charge refrigerant referring to “Evacuating of A/C System” and “Charging of A/C System” in Operation Procedure for Refrigerant Charging .
Tightening torque
Refrigerant pressure sensor : 9.0 N·m ( 0.9 kg-m, 6.5 lb-ft)