Reverse removal procedure to install desiccant noting the following instructions.
•
Do not remove desiccant from the plastic bag until just before inserting it into the receiver.
•
Replenish specified amount of compressor oil to compressor suction side by referring to “Replenishing Compressor Oil” in
Operation Procedure for Refrigerant Charging
.
•
Sufficiently apply compressor oil to the fitting surface of the O-ring and the cap.