Item No.
|
Symptom
|
Charge of refrigerant
|
Correction
|
---|
1
|
Bubbles observed in sight glass
|
Insufficient charge of refrigerant in system
|
Check system for leaks with a leak tester.
|
2
|
No bubbles observed in sight glass
|
No or insufficient charge of refrigerant in system
|
Refer to the items 3 and 4.
|
3
|
No temperature difference between compressor inlet and outlet
|
Empty or nearly empty system
|
Evacuate and charge system and then check it for leaks with a leak tester.
|
4
|
Noticeable temperature difference between compressor inlet and outlet
|
Proper or too much charge of refrigerant in system
|
Refer to the items 5 and 6.
|
5
|
When A/C is turned OFF, refrigerant in sight glass clears immediately and remains clear
|
Too much charge of refrigerant in system
|
Discharge excess refrigerant in order to obtain a specified charge.
|
6
|
When A/C is turned OFF, refrigerant in sight glass once produces bubbles and then clears
|
Proper charge of refrigerant in system
|
No correction needed because charge of refrigerant is normal.
|