| Item No. | Symptom | Charge of refrigerant | Correction |
|---|---|---|---|
| 1 | Bubbles observed in sight glass | Insufficient charge of refrigerant in system | Check system for leaks with a leak tester. |
| 2 | No bubbles observed in sight glass | No or insufficient charge of refrigerant in system | Refer to the items 3 and 4. |
| 3 | No temperature difference between compressor inlet and outlet | Empty or nearly empty system | Evacuate and charge system and then check it for leaks with a leak tester. |
| 4 | Noticeable temperature difference between compressor inlet and outlet | Proper or too much charge of refrigerant in system | Refer to the items 5 and 6. |
| 5 | When A/C is turned OFF, refrigerant in sight glass clears immediately and remains clear | Too much charge of refrigerant in system | Discharge excess refrigerant in order to obtain a specified charge. |
| 6 | When A/C is turned OFF, refrigerant in sight glass once produces bubbles and then clears | Proper charge of refrigerant in system | No correction needed because charge of refrigerant is normal. |