Check fluid passage of relief valve and orifice of connector for obstruction (clogged).
•
Check sliding surface of relief valve for wear and damage.
•
Check free length of relief valve spring (1).
Replace pump assembly if any defective is found.
Relief valve spring free length
Standard: 36.5 mm (1.44 in.)
Limit: 33.5 mm (1.32 in.)