5B
Gear Shift Fork Inspection
1) Using feeler gauge, check clearance between fork (1) and sleeve (2) and replace those parts if it exceeds limit below.
NOTE:
For correct judgement of parts replacement, carefully inspect contact portion of fork and sleeve.
Clearance between fork and sleeve
Service limit “a”: 1.0 mm (0.039 in.)
2) Insert each gear shift shaft into case and check that it moves smoothly. If it doesn't, correct using oilstone, reamer or the like.