Transmission Case Inspection
Measure inner diameters “a” and “b” of transmission case bush. When either measured value exceeds limit value, replace it.
Transmission case bush bore limit
“a”: 36.11 mm (1.422 in.)
“b”: 35.40 mm (1.394 in.)