3C
Transfer Shift Actuator Inspection
Inspect operation of transfer shift actuator as follows.
If actuator does not work correctly, replace actuator assembly.
1) Remove transfer shift actuator referring to Transfer Assembly Disassembly and Reassembly .
2) Connect 2 dry cell batteries in series.
3) Connect battery (+) to “a”, (–) to “f” and service wire (1) to “c” and “e” respectively, then change motor position from 4H to 4L.
4) Connect battery (+) to “f”, (–) to “d” and service wire (1) to “c” and “e” respectively, then change motor position from 4L to 4H.
5) Connect battery (+) to “f”, (–) to “a” and service wire (1) to “c” and “e” respectively, then change motor position from 4H to 2H.
6) Connect battery (+) to “b”, (–) to “f” and service wire (1) to “c” and “e” respectively, then change motor position from 2H to 4H.
2. Dry cell battery of 1.5 V
Limit switch circuit table