1C
Boost Pressure Control Solenoid Valve Inspection
2)
Check for resistance between boost pressure control solenoid valve terminals.
If resistance is not as specified, replace boost pressure control solenoid valve.
Boost pressure control solenoid valve resistance
18.9 – 23.1 Ω at 23 °C (73.4 °F)
3)
Apply vacuum 80 kPa (0.8 kg/cm² 11.5 psi) to boost pressure control valve using special tool. If vacuum can be applied, go to the next step. If not, replace boost pressure control valve.
Special Tool
(A)
:
09917–47011
4)
Connect 12 V battery to boost pressure control valve terminals. In this state, apply vacuum 70 kPa (0.7 kg/cm² 10.1 psi) to the outlet nozzle using a special tool. If vacuum can not be applied, boost pressure control valve is in good condition. If not, replace boost pressure control valve.
Special Tool
(A)
:
09917–47011
(B)
:
09918–08210
[A]:
|
Pipe to vacuum pump
|
[B]:
|
Pipe to waste gate actuator
|