Step | Action | YES | NO |
---|---|---|---|
1 |
Is SUZUKI scan tool available?
|
Go to Step 2.
|
Go to Step 3.
|
2 |
Check electric load signal circuit
2)
Start engine and select “DATA LIST” mode on scan tool.
Is check result satisfactory?
|
Electric load signal circuit is in good condition.
|
“RED/WHT”, “RED/YEL” and/or “BLU/ORN” circuit open or short, electric load diodes malfunction or each electric load circuit malfunction.
|
3 |
Check electric load signal circuit
1)
Turn ignition switch ON.
2)
Check voltage at each terminals “E114-12”, “E114-17” and “E113-13” of ECM connector connected, under above each condition.
Is each voltage as specified?
|
Electric load signal circuit is in good condition.
|
“RED/WHT”, “RED/YEL” and/or “BLU/ORN” circuit open or short, electric load diodes malfunction or each electric load circuit malfunction.
|